8 Using the SIMM for IPDS with the
Adapter for SCS
8.1 Using the Coax/Twinax Adapter for SCS
This section describes how to set up the Adapter for SCS to make it possible to print
IPDS data to either a direct coaxially attached printer or a direct twinaxially attached
printer. Please refer to Appendix A for a list of compatible hardware attachments and
supported host software.
Adapter for SCS Code Levels Required
H01-9072 (or greater) for coax
H02-8491 (or greater) for twinax
To see the Adapter for SCS code level, you need to use the printer's operator panel.
The last four digits (in "8491") are the ones you want to be greater than or equal to.
To print a Firmware Summary, follow these steps
1. When Ready or Power Saver displays in the operator panel, press Menu>
to move to NETWORK MENU. Press Select. You will then see
NETWORK OPTION 1, NETWORK OPTION 2 or NETWORK
OPTION 3 display. Pick the number corresponding to the option slot the
adapter is installed in. Press Select.
2. Press Menu> until you see SCS MENU 1, SCS MENU 2 or SCS MENU 3
display.
3. Press Select. Press Menu> until you see TESTS OPTIONS.
4. Press Select. Firmware Summary displays. Press Select.
5. Press Menu> until you see Print. Press Select. A short report listing the
revision numbers will print.