Lexmark 3455 User Manual Page 134

  • Download
  • Add to my manuals
  • Print
  • Page
    / 181
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 133
134
MarkNet internal print server, MarkNet Pro external print server, or MarkNet
XLe “end-of-job-timeout”
The recommended setting for the MarkNet internal print server, MarkNet Pro
external print server, or MarkNet XLe end-of-job-timeout is 0 (disabled). This
allows the host timer/timeout value or printer IPDS Timeout value (when using a
MarkNet internal print server only) to control when print jobs from another
protocol, interface, server, or host can be started.
You may set the MarkNet internal print server, MarkNet Pro external print server,
or MarkNet XLe end-of-job-timeout to a value greater than the host timer/timeout
value or printer IPDS Timeout value (when using MarkNet internal print server
only). Errors are very likely to occur when the printer requires user intervention
and the intervention is not cleared before the end-of-job-timeout occurs.
Setting the MarkNet internal print server, MarkNet Pro external print server, or
MarkNet XLe end-of-job-timeout smaller than the host timer/timeout value or
printer IPDS Timeout value (when using a MarkNet internal print server only)
will result in communication errors after the job has printed.
For additional information on setting the end-of-job-timeout, refer to chapter 7
Using the SIMM for IPDS with a MarkNet Internal or External Print Server on
page 83.
MarkNet Pro Busy Timeout
The recommended setting for the MarkNet Pro Busy Timeout is 0 (disabled).
This allows the host timer/timeout value to control when print jobs from another
protocol, interface, server, or host can be started.
You may set the MarkNet Pro Busy Timeout to a value greater than the host
timer/timeout value. Errors are very likely to occur when the printer requires user
intervention and the intervention is not cleared before the end-of-job-timeout
occurs.
Setting the MarkNet Pro Busy Timeout smaller than the host timer/timeout value
will result in communication errors after the job has printed.
For additional information on setting the Busy Timeout, refer to section 7.3.4
Setting the MarkNet Pro Busy Timeout on page 88.